AQUARITE CHLORINE
GENERATOR
TURBO
CELL MAINTENANCE TIPS
*SAFETY
FIRST USE SAFETY GLASSES AND CHEMICAL PROOF GLOVES AVOID SKIN AND EYE
CONTACT
<>Cell cleaning
frequency is dependent on several factors. pH and calcium levels in the
water are the two that have the greatest effect on how often the cell
requires cleaning.
Maintaining
pH at
the levels recommended in the Operating Instructions (7.2 - 7.8) should
result in cell cleaning 3-4 times a year in areas with hard water.
Cells can be cleaning less frequently in soft water areas.
The cell will require maintenance when the "Inspect Cell" light is
either flashing or is on solid and the salt level is confirmed to be
above 2500 part per million.
- Turn Filter pump off.
- Remove the AquaRite Turbo Cell from its position in the
plumbing by loosening the unions on both ends of the cell.
- You will need a small plastic bucket (6 - 8" opening),
water and muriatic acid. (Picture A) (muriatic acid can be purchased at
hardware stores pool stores home centers)
- Fill the bucket with 3 - 4" of water. (Picture B)
- Set the Turbo Cell, on end, in the bucket of water.
(Picture C)
- Add 1 - 1 1/2" of muriatic to the water in the bucket. Let
the cell sit in this solution for 5-10 minutes. (Picture D)
- Turn the cell over and let the other end sit in the
solution for 5 - 10 minutes. You will be
submersing the cord, which will not be affected by the mild acid
solution. (Picture E)
Look in both ends of the cell to confirm calcium deposits are removed.
If not, repeat cleaning procedure.
- Rinse cell with fresh water and replace in plumbing line.
Hand tighten unions before restoring power to filter pump.
|